|
The data were processed by Dan Torres, WHOI:
The shipboard ADCP data collected for cruise SKQ14S came from two instruments,
the 300 kHz Workhorse and the 75 kHz Ocean Surveyor. The raw data were collected
using Univ. of Hawaii UHDAS software. Collected data were processed using CODAS
software. Data were processed in 3 parts using 2 cruises. The first cruise had
2 parts. Part A1 represents a time frame before we raised the center board and
Part A2 was after we lowered the centerboard and restarted data acquistion.
Although the data were broken up into different parts for processing, all the
parts were combined to produce a single file for the final processed data. So
the user does not really have to be concerned with all the details involved
to get to that point. There are 2 final files, one for the WH300 and 1 for
the OS75.
AON20_sect0_os75_dt_v1.mat
AON20_sect0_wh300_dt_v1.mat
Details of the calibration are described in SKQ202014S_ADCP_Calibration_report.txt.
Processing steps and even more details are provided in the documents
- WH300 data part A
- OS75 data part A
- WH300 data part B
- OS75 data part B
The issue is there appeared to be a change in the calibration when lowering the
centerboard. So the cal we started with was no longer valid. So the plan was to
reprocess Part A1 to determine a cal offset. In theory, the new cal for Part A1
should be the same as the original cal we started with.
I applied the new cal for A1 to the whole cruise A because it was easier that way.
But I only used data from A1. Then I determined a new cal for the A2 time period.
Once a new cal was determined, it was applied to the whole cruise A (a second copy)
but only used part A2.
These are:
# heading alignment: nominal - (cal/watertrack)
h_align = dict(
wh300 = 44.93, # 44.13 - (-0.8) Sikuliaq's returned to service SKQ202012S
os150 = 45.53,
os75 = 45.2,
)
# transducer depth, meters
ducer_depth = dict(
wh300 = 7,
os150 = 6,
os75 = 6,
)
Using these numbers for cruise B, the cal looked spot on. Either CODAS is doing
a good job of calibrating on the go for cruise B or the instrument got put back
exactly in the right position. How can I tell?
Here is the command I used to compare reference layers between OS75 and WH300.
codaspy:(vmpro_A)$ plot_reflayer.py --zrange 0:45 --ddrange 209:300 --plotfp
--title PartA1 --outbase save figs:part_A1
/media/sf_vmraw/SKQ202014S_save2/proc/wh300
/media/sf_vmraw/SKQ202014S_A/proc/os75nb
codaspy:(vmpro_A)$ pwd
/media/sf_vmraw/vmpro_A
codaspy:(vmpro_A)$ plot_reflayer.py --zrange 0:45 --ddrange 209:300 --plotfp
--title PartA1 --outbase part_A1
/media/sf_vmraw/SKQ202014S_save2/proc/wh300
/media/sf_vmraw/SKQ202014S_A/proc/os75nb
======> NOTE ABOUT CALIBRATIONS <=======
If there was a reason to apply a calibration
to os75nb for it to better match wh300,
these are APPROXIMATE values to use.
Use these as if they came from cal/watertrk or cal/botmtrk.
scale factor:f 1.028 to os75nb
rotation angle: -0.02deg to os75nb
================
|