AON20 Cruise ADCP Calibration Report (preliminary) ==================================== This report describes the steps taken to calibrate the WH300 ADCP used on R/V Sikuliaq for cruise SKQ202014S for AON 2020 project. The goal of calibration is to determine the transducer misalignment error. The WH300 ADCP was mounted with two forward beams rotated 45 degrees from the center line. This is standard practice to reduce the magnitude of the along-track component of measured velocity. Calibration from previous cruises determined the transducer alignment to be 44.93 degrees. We started this cruise with that number entered in the file SKQ202014S_proc.py.txt. This file was generated in the reports directory as a copy of the original used when starting a new cruise with UHDAS. Any future calibration or rotation will be relative to that number. The initial data quality and calibration were found to be excellent. However, due to heavy ice conditions, it was decided it was nnecessary to raise the centerboard to a safe position inside the hull of the ship. The WH300 acquisition was turned off for approximately two days. Once the WH300 was turned back on, we noticed some behavior in processed data usually indicative of incorrect calibration. We noticed some velocity vectors changed along with ship turns. After some discussion we decided there was a possibility that the WH300 orientation could change between subsequent centerboard raising and re-lowering operations. Although the mechanical installation and stiffening bladder was designed to maintain a constant orienation, there could be enough play in the system to allow for a shift in orientation. So we decided a new calibration was necessary. The collected data were divided into 3 parts as described below. Part 1 - Cruise A ADCP Start_date_time Decimal_Day End_date_time Decimal_day WH300 2020/10/16 01:06:12 209.0460 2020/10/27 16:07:55 300.6722 Part 2 - Cruise A ADCP Start_date_time Decimal_Day End_date_time Decimal_day WH300 2020/10/29 11:43:37 302.4886 2020/11/01 15:54:00 305.6625 Part 3 - Cruise B ADCP Start_date_time Decimal_Day End_date_time Decimal_day WH300 2020/11/04 05:44:06 308.2390 ... still going .... Results of BT and WT calibration for Part A1 BT median mean std points amplitude 0.9878 0.9880 0.0054 954/1030 phase -0.0513 -0.0453 0.0697 WT (nrefs=7) median mean std points amplitude 0.9980 0.9954 0.0109 32/34 phase -0.1675 -0.1530 0.4095 Since the std of the BT measurements were lower than the WT std, we would generally give more weight to the BT calibration results. From these results, we could apply an additional rotation of phase angle = -0.05 deg and amplitude = 0.9980. But one can argue that no further rotation is necessary and these numbers were within generally established tolerances (0.1 deg) Results of BT and WT calibration for Part A2 WT nrefs 5 7 9 mean(std) amplitude 1.0049(0.0163) 1.0003(0.0191) 1.0080(0.0035) phase -0.2824(0.7302) -0.9087(1.1450) -0.9597(0.6835) pts used/ 14/24 7/13 3/5 total number BT median mean std pts_used/Tot amplitude 1.0024 1.0022 0.0029 42/47 phase 0.0000 -0.0137 0.1570 Worthy of note is that ice conditions were heavy during Part A2. Also, much fewer BT and WT data were available for calibration. Once again the std of the BT cal results were better than those of the WT cal. The phase angle from this calibration is -0.01 deg. The difference between the Part A2 and Part A1 phase angles = 0.04 deg. The standard deviation of each of the respective calibrations (0.06 and 0.16) was larger than the difference in phase angles. So at this point we conclude that there is a negligible difference in calibration between Parts A1 and A2. An additional check to determine if the act of raising and re-lowering the centerboard had an effect on the ADCP orientation is examined with Cruise B. The centerboard was raised once again to traverse through the ice. A new cruise was started with the same original misalignment correction used in Cruise A. Below are those calibration results as of 2020/11/8 04:31:11. BT median mean std pts_used/Tot amplitude 1.0112 1.0105 0.0045 480/516 phase -0.0508 -0.0607 0.0800 WT median mean std pts_used/Tot amplitude 0.9980 0.9968 0.0077 98/102 phase 0.0430 0.0711 0.5411 nav - pc 0.0000 -0.2959 1.7715 This calibration is within 0.01 degress of the previous cal. Therefore we determine that the transducer misalignment angle did not change due to raising and lowering of the centerboard. One additional point to consider. During the cruise, we found an occasional bias in the WH300 and OS75 measurements. The most likely source of this bias is concurrent EM302 Multibeam pinging. Since the multibeam ping rate is dependent on depth, so is the interference. An attempt will be made to isolate the interference and edit those ADCP data affected with CODAS gautoedit processing. Once that is done, new calibrations will be calculated. Since removing bias generally improves calibrations, we do not believe those efforts will have significant impact on the calibration results presented here.