2013/10/07 first: setup the tripod CT1, for the underice bloom project. 48m depth Use SUNA arctic winch #8 set to profile daily at local noon (1900 GMT) limit to 10m below the ice. With added safety of 4m due to spooling discrepancies etc, 2m offset between top of float and base of tripod, and 48m water depth, this came out to 32m line. I calibrated the line-out to have the winch pull back at 8400 counts. The daily profiles were programmed to start on Oct 15, 19:00. microcat #2132, 100m depth limit, with p set to usual 15m sampling. started onboard. WH300 ser# 2226 set to usual hourly sampling, started onboard restarted once after it was already mounted on the tripod on deck: double-check that clock was set. It was ============================ 2013/10/10 setup for BOEM tripd CS1: WH300 ser# 14445 set to usual hourly sampling, started onboard use microcat #2135 set to usual 15m sampling. started onboard. use Arctic Winch #3 (the old style without SUNA) ============================= 2013/10/08 setup for BOEM mooring CS2 WH300 ser# 17123 set to usual hourly sampling, started onboard restarted once to set clock. use microcat #2133 set to usual 15m sampling. started onboard. CMP setup: as of 2013/10/09, preliminary mooring depths have the CMP wire at 40 - 87m. With Bob's 2m safety, that becomes 42 - 85m. Note that we might have to re-program once the moorings have been surveyed. But re-programming is easier than starting from scratch. Use CMP#2, which has an FSI CTD Version: MMP-3_04.c S/N: ML11903-01B 2013/10/10 change: switch to CMP #8. This one has a SUNA. Because of Bob's desire to profile 4/day, he asked to disable SUNA, which I just did. Because it might still, for unknown reason, use more battery power, we decided to put this on onto CS2. This CMP also has an RBR CTD, which does not remove atm. pressure. Hence the programming actually sets a range of 52-95m. Configuration: MMP_CT_NI Version 4_12 of Apr 23 2010 McLane Research Laboratories, USA McLane Moored Profiler S/N: ML12535-02 ================================== 2013/10/09 setup for BOEM mooring CS3 LR75 #19517 set to usual hourly sampling, started onboard restarted once to set clock. use microcat #2136 set to usual 15m sampling. started onboard. CMP setup: as of 2013/10/09, preliminary mooring depths have the CMP wire at 40 - 236m. With Bob's 2m safety, that becomes 42 - 234m. Note that we might have to re-program once the moorings have been surveyed. But re-programming is easier than starting from scratch. Use CMP#3, which has an FSI CTD Version: MMP-3_04.c S/N: ML1066192077 2013/10/10 Find typo in the mooring diagrams, reprogram: still use CMP #3, but for depth range of 40-148m With Bob's 2m safety, that comes to 42 to 146m ================================== setup for BOEM mooring CS4 LR75 #15440 set to usual hourly sampling, started onboard restarted once to set clock. use microcat #5926 set to usual 15m sampling. started onboard. CMP setup: use CMP #2 now, after 8 got assigned to mooring CS2 CMP #2 has FSI CTD Version: MMP-3_04.c S/N: ML11903-01B depth ranges: 40 - 237m with Bob's 2m safety, that come to setting 42 - 235m (FSI has no pressure offset) ================================== 2013/10/10 setup for BOEM mooring CS5 CMP setup: use CMP #1, has FSI CTD McLane Research Laboratories, USA McLane Moored Profiler Version: MMP-3_04.c S/N: ML1066192077 depth ranges: 40 - 344m with Bob's 2m safety, that come to setting 42 - 342m (FSI has no pressure offset) use microcat #5083 set to usual 15m sampling. started onboard. LR75 #15483 set to usual hourly sampling, started onboard ================================== ================================== 2013/10/10 setup for AON mooring BS3 CMP setup: use CMP #9. Configuration: MMP_CT_NI V4_17 of Apr 29 2011 McLane Research Laboratories, USA McLane Moored Profiler S/N: ML12742-01 This one has a SUNA. We will use 2 profiles / day. The profiling range is 39 - 137m (mooring diagram notes). With Bob's 2m safety, that come sto 41 - 135 This CMP also has an RBR CTD, which does not remove atm. pressure. Hence the programming actually sets a range of 51 - 145m. 2013/10/18 re-programmed to 6-hourly profiles, like the other CMPs (initial programming was 12-hourly for this one) use microcat #5084 set to usual 15m sampling. started onboard. LR75 #10365 set to usual hourly sampling, started onboard --------------------------------------------------------------- 2013/10/24 microcat for FM1 ser# 2131 install new batteries on 2013/10/24 as well as new poison pills RS485 id01 instrument still had previous settings stored. However, I did have to set the clock. start sampling now. ---------------------------------------------------------------------- 2013/10/24 WH300 for FM1 ser# 2127 had changed O-ring yesterday installed new battery shipped by Dan fired up with BBTALK, using its own power hooked up new batt today -------------------------------------------------------------------- 2013/10/25 CMP setup for FM1 Configuration: MMP_CT_NI V4_17 of Apr 29 2011 McLane Research Laboratories, USA McLane Moored Profiler S/N: ML12742-02 ser# 10, recovered from BS3 received and installed batt yesterday sealed ball yesterday, held pressure overnight installed ball this morning tested CTD and motor functions disable SUNA => 6-hourly has less than 4098 files reprogrammed: cycling depth 39-58m add 10 for RBR: 49 - 68 set 1m safety: 50m - 67m files per fileset: 1 (firmware 4.17 bug loses second file in fileset > 1)