Layla; 2013/10/17 (GMT) download WH300 from BS3 sphere ser# 1393 check clock with bbtalk, download data with winsc GMT 2013/10/17 01:08:42 TT 2013/10/17,01:01:00 - Time Set (CCYY/MM/DD,hh:mm:ss) instrument 00:07:42 slow --------------------------------- connect to CMP from BS3: use GMT: 2013/10/17 02:28:42 CMP: 2013/10/17 02:30:30 could not unpack with version 2.26 or 2.32. Used unpacker 3, which only gave every other CTD file. Very odd, since all engineering files were there, thus the CTD had to be on for all profiles. Also, all SUNA files were there. will check with McLane upon return -------------------------------------- BS3 microcat from sphere: connector got sheared off. Connected via make-shift connector to inside molex between battery cage. When I made contact, clock had reset to 1980, and storage was empty. ---------------------------------- from Lukas BS3 LR75 # 1468 checked clock: found LR75 to be 5 min 17 seconds late. Instrument required outside power to wake up last ensemble in raw data: 2012 10 28 1 0 0 ----------------------------------------------------------------- 2013/10/18, Layla BPR ser# 5338640-0007 hook up with cable provided by Rick: 4-pin coms connector is up on right. Seasoft_Waves, SeatermW got BPR to respond, but only to say "low battery". Change batteries. clock check: GMT: 2013/10/18 22:15:00 BPR: 2013/10/18 22:15:30 => BPR 30 seconds fast. in SeatermW: upload. It asks for file name, which I provide. Upload took a few minutes. To convert uploaded .hex file, use Seasoft for Waves again. But first: in SeatermW, turn capture on, then hit coefficients. Then return to Seasoft for Waves and compare: ... well, not clear whether the coefficients reported by the sensor need to be entered into SeasoftWaves - their names differ, and the menusays "T,C coefficients not used for SBE53", which this is. Slope and offset are set to 1 and 0, respectively. The sensor capture includes offset, indicatedas 0. So: proceed without setting coefficients. Sensor contained data until Sept. 9, 2013. ----------------------------------------------------------------------- 2013/10/18, Layla ULS ser# IPS4 41043 start ASL IPSLink (not IPS5LINK used for IPS5) connect cable and power supply, hit reset button hit "detect unit", and find it. hit "Date/Time", " continuously acquiring date/time from unit". Find that the ULS is 45 seconds fast. GMT 2013/10/18 23:30:00 ULS 2013/10/18 23:30:45 hit "recover files from unit", follow that menu -------------------------------------------------- 2013/10/20 microcat 2134 from BS3 LR75 frame. Downloaded already to fb8100, repeat onto Layla today. Clock: mc 2 minutes fast ------------------------------------------------ ========================================== 2013/10/21 (GMT) microcat 2131 from AG1 sphere clock check: clock is fast by 1 min 48 sec However, date is way off!! says: July 24, 2013. GMT: Oct 21, 2013 ---------------------------------------------------- 2013/10/21 WH300 from AG1 sphere , ser# 2127 clock check with bbtalk GMT 14:42:59 ADCP: 14:29:47 can not say "hi" without external power ------------------------------------------ on lukas: 2013/10/21 AG1 LR75 check clock with bbtalk: GMT 14:01:42 LR75: 2013/10/21,13:58:30 download with winsc: failed on its own batt. try with power supply: worked fine ---------------------------------------- 2013/10/21 AG1 mc from LR75 cage ser# 5925, rs232 mc 2 min 23 sec slow