Deployment 2009 to 2010:
calibration info for SBE37 #2136




The calibration adjustments were based on the drift determined from the laboratory calibrations at SeaBird before and after the deployment. The SeaBird sheets, while very helpful, can be confusing at first sight (they have confused me in the past).

Temperature:
The plot below shows the lower portion of the SeaBird calibration sheet for the Jan 19 2011 post-cruise calibration. The triangles close to the zero line represent the residuals from fitting bath temperatures to SBE37 output using the new (2011) calibration values. The circles indicate the residuals when using the same 2011 measurements, but converting the SBE37 raw frequency output to temperatures via the calibration coefficients determined back on March 31, 2009. In other words: without recalibrating the sensor (i.e., leaving it with the 2009 cal), in January of 2011 the SBE37 measured temperature too low. SeaBird determined the offset to be -0.00062 ° C when averaged over the whole calibration range. However, for the temperature range we obeserved in the field between 0 and 10 ° C, it was about -0.00075 ° C.



Without further knowledge, the simplest model would be to assume that the sensor drifted linearly in time. It is further generally assumed that the drift occurs primarily during sensor deployment, when the sensor was actually in the ocean. There are then two possible approaches for applying a correction:

1)     use the 2011 calibration coefficients to re-generate temperatures from sensor frequencies contained in the raw data file, presumably via SeaBird programs; then adjust linearly from maximum correction at the deployment start (when the 2009 calibration was correct) to zero correction at the end (when the 2011 calibration was correct).

2)     start with the existing temperature data file generated with the 2009 calibration, and adjust it linearly from zero correction at deployment to maximum correction at recovery.

For simplicity, we chose the second approach. To correct our field measurements, we therefore added an offset that varied linearly from zero upon deployment to +0.00075 ° C on recovery. The plot below displays the correction applied to the temperature record.




Conductivity:
The conductivity correction followed a similar scheme. Again, the first plot below shows the figure portion of the SeaBird post-cruise calibration sheet. In this case, using the March 2009 calibration coefficients showed residuals for the 2011 calibration measurements to be negative: i.e., the conductivity in the data file generated with the pre-cruise calibration was too low at the end of the deployment. In contrast to temperature, however, the correction itself was a linear funtion of conductivity ("slope correction").



As for temperature, we chose to use the 2009 cal to convert sensor frequencies into engineering data (conductivity), then linearly adjusted from zero slope correction at deployment time to full post-cruise calibration slope correction on recovery. The actual correction in terms of S/m subtracted from the original record (shown again in the lower panel of the plot below) varied roughly linearly from 0 to 0.00025 S/m over the time the sensor was in the ocean. It was of course close to zero at the very end when the sensor was back on deck but not yet turned off, as conductivity itself was zero then.




Pressure:
The pressure sensor tends to be quite stable. This was confirmed by the SeaBird post-deployment calibration. The plot below again shows the figure portion of the SeaBird calibration sheet. Since residuals are expressed in "percent full scale", I also included the table portion of the cal sheet, which indicated residuals to be within 0.01 dbar (0.01 to 0.02 psi).